Skip to content

Start PROFIBUS DP Master Node

Industrial/PROFIBUS

Start native cyclic DP-V0 exchange on an RS-485 serial adapter using device GSD parameter bytes

industrial_profibus_connectindustrial
Inputs2
Outputs2
Security exposureUnrated
Packageindustrial

Ratings

Scores range from 0 to 10. Higher values mean more impact, exposure, or operational weight.

No score metadata has been set for this node yet.

Input Pins

2

Input

Execution
exec_in

Run this operation

Configuration

Struct
request

Inputs and configuration

ProfibusConfigProfibusConfig10 fields
portstringrequired

Serial device connected to an RS-485 adapter with automatic direction control.

baud_rateinteger:uint32required
format uint32min 0
master_addressinteger:uint8required
format uint8min 0max 255
highest_station_addressinteger:uint8required
format uint8min 0max 255
slot_bitsinteger:uint16required
format uint16min 0max 65535
poll_interval_usinteger:uint64required
format uint64min 0
watchdog_msinteger:uint64required
format uint64min 0
retry_limitinteger:uint8required
format uint8min 0max 255
modeProfibusModerequired
enum "stop", "clear", "operate"
peripheralsArray<ProfibusPeripheralConfig>required
itemsProfibusPeripheralConfigarray item
addressinteger:uint8required
format uint8min 0max 255
ident_numberinteger:uint16required
format uint16min 0max 65535
user_parametersArray<integer:uint8>required

Device-specific bytes derived from its GSD and selected modules.

itemsinteger:uint8array item
format uint8min 0max 255
configurationArray<integer:uint8>required
itemsinteger:uint8array item
format uint8min 0max 255
input_bytesinteger:uintrequired
format uintmin 0
+4 more fields
Schema enforced

Output Pins

2

Done

Execution
exec_out

Operation completed

Result

Struct
result

Operation result

SessionSession2 fields
ref_idstringrequired
protocolstringrequired

Node Info

Internal name
industrial_profibus_connect
Category
Industrial/PROFIBUS