Ratings
Scores range from 0 to 10. Higher values mean more impact, exposure, or operational weight.
No score metadata has been set for this node yet.
Input
Executionexec_in
Run this operation
Configuration
Structrequest
Inputs and configuration
requestModbusReadRequestrequired
unit_idinteger:uint8required
format uint8min 0max 255
kindModbusReadKindrequired
enum "coils", "discrete_inputs", "holding_registers", "input_registers"
start_addressinteger:uint16required
format uint16min 0max 65535
countinteger:uint16required
format uint16min 0max 65535
timeout_msinteger:uint64required
format uint64min 0
Schema enforced
Done
Executionexec_out
Operation completed
Result
Structresult
Operation result
variant 1objectvariant
kindconstrequired
const "registers"
valuesArray<integer:uint16>required
itemsinteger:uint16array item
format uint16min 0max 65535
variant 2objectvariant
kindconstrequired
const "bits"
valuesArray<boolean>required
Node Info
- Internal name
- industrial_modbus_read
- Category
- Industrial/Modbus