Skip to content

Write Logix Tag Node

Industrial/EtherNet IP

Write a typed Logix tag through CIP explicit messaging

industrial_cip_writeindustrial
Inputs2
Outputs2
Security exposureUnrated
Packageindustrial

Ratings

Scores range from 0 to 10. Higher values mean more impact, exposure, or operational weight.

No score metadata has been set for this node yet.

Input Pins

2

Input

Execution
exec_in

Run this operation

Configuration

Struct
request

Inputs and configuration

CipWriteRequestCipWriteRequest3 fields
sessionSessionrequired
ref_idstringrequired
protocolstringrequired
tagstringrequired
valueCipValuerequired
variant 1objectvariant
typeconstrequired
const "bool"
valuebooleanrequired
variant 2objectvariant
typeconstrequired
const "sint"
valueinteger:int8required
format int8min -128max 127
variant 3objectvariant
typeconstrequired
const "int"
valueinteger:int16required
format int16min -32768max 32767
variant 4objectvariant
typeconstrequired
const "dint"
valueinteger:int32required
format int32
variant 5objectvariant
typeconstrequired
const "lint"
valueinteger:int64required
format int64
+8 more fields
Schema enforced

Output Pins

2

Done

Execution
exec_out

Operation completed

Result

Boolean
result

Operation result

Node Info

Internal name
industrial_cip_write
Category