Skip to content

Write ADS Node

Industrial/ADS

Write bytes to a named PLC symbol or ADS index address

industrial_ads_writeindustrial
Inputs2
Outputs2
Security exposureUnrated
Packageindustrial

Ratings

Scores range from 0 to 10. Higher values mean more impact, exposure, or operational weight.

No score metadata has been set for this node yet.

Input Pins

2

Input

Execution
exec_in

Run this operation

Configuration

Struct
request

Inputs and configuration

AdsWriteRequestAdsWriteRequest3 fields
sessionSessionrequired
ref_idstringrequired
protocolstringrequired
addressAdsAddressrequired
variant 1objectvariant
namestringrequired
kindconstrequired
const "symbol"
variant 2objectvariant
groupinteger:uint32required
format uint32min 0
offsetinteger:uint32required
format uint32min 0
kindconstrequired
const "index"
dataArray<integer:uint8>required
itemsinteger:uint8array item
format uint8min 0max 255
Schema enforced

Output Pins

2

Done

Execution
exec_out

Operation completed

Result

Boolean
result

Operation result

Node Info

Internal name
industrial_ads_write
Category